Skip to content

Telegraf reports more than 100% cpu usage and negative values on a 40 logical cores system #18141

Closed

Description

Relevant telegraf.conf

[[inputs.win_perf_counters.object]]
# Processor usage, alternative to native, reports on a per core.
 ObjectName = "Processor"
 Instances = ["*"]
 Counters = ["% Idle Time", "% Interrupt Time", "% Privileged Time", "% User Time", "% Processor Time"]
 Measurement = "win_cpu"
 IncludeTotal=true

[[inputs.cpu]]
 percpu = true
 totalcpu = true
 collect_cpu_time = false
 report_active = false

Logs from Telegraf

2025-12-17T14:42:52Z I! Starting Telegraf 1.37.0 brought to you by InfluxData the makers of InfluxDB
2025-12-17T14:42:52Z I! Available plugins: 242 inputs, 9 aggregators, 35 processors, 26 parsers, 67 outputs, 7 secret-stores
2025-12-17T14:42:52Z I! Loaded inputs: cpu disk diskio internal mem net netstat procstat system win_perf_counters
2025-12-17T14:42:52Z I! Loaded aggregators:
2025-12-17T14:42:52Z I! Loaded processors:
2025-12-17T14:42:52Z I! Loaded secretstores:
2025-12-17T14:42:52Z I! Loaded outputs: influxdb (2x)
2025-12-17T14:42:52Z I! Tags enabled: IP=0.0.0.0 environment=VAL host=hostname.example.com machine_type=physical os_type=Win32NT os_version=Microsoft Windows Server 2022 Standard 10.0.20348.0 region=N/A
2025-12-17T14:42:52Z W! Deprecated inputs: 0 and 1 options
2025-12-17T14:42:52Z I! [agent] Config: Interval:10s, Quiet:false, Hostname:"hostname.example.com", Flush Interval:10s
2025-12-17T14:42:52Z W! [agent] The default value of 'skip_processors_after_aggregators' will change to 'true' with Telegraf v1.40.0! If you need the current default behavior, please explicitly set the option to 'false'!
2025-12-17T14:43:10Z E! [inputs.cpu] Error in plugin: current total CPU time is less than previous total CPU time
2025-12-17T14:43:30Z E! [inputs.cpu] Error in plugin: current total CPU time is less than previous total CPU time
2025-12-17T14:46:20Z E! [inputs.cpu] Error in plugin: current total CPU time is less than previous total CPU time
2025-12-17T14:47:10Z E! [inputs.cpu] Error in plugin: current total CPU time is less than previous total CPU time
2025-12-17T14:49:59Z I! [agent] Hang on, flushing any cached metrics before shutdown
2025-12-17T14:49:59Z I! [agent] Stopping running outputs
2025-12-17T14:50:00Z W! Strict environment variable handling will be the new default starting with v1.38.0! If your configuration works with strict handling or you don't use environment variables it is safe to ignore this warning. Otherwise please explicitly add the --non-strict-env-handling flag!
2025-12-17T14:50:00Z I! Loading config: C:\\Program Files\\InfluxData\\telegraf-1.37.0\\telegraf.conf
2025-12-17T14:50:00Z W! DeprecationWarning: Option "ignore_protocol_stats" of plugin "inputs.net" deprecated since version 1.37.0 and will be removed in 1.45.0: option is ignored
2025-12-17T14:50:00Z I! Starting Telegraf 1.37.0 brought to you by InfluxData the makers of InfluxDB
2025-12-17T14:50:00Z I! Available plugins: 242 inputs, 9 aggregators, 35 processors, 26 parsers, 67 outputs, 7 secret-stores
2025-12-17T14:50:00Z I! Loaded inputs: cpu disk diskio internal mem net netstat procstat system win_perf_counters
2025-12-17T14:50:00Z I! Loaded aggregators:
2025-12-17T14:50:00Z I! Loaded processors:
2025-12-17T14:50:00Z I! Loaded secretstores:
2025-12-17T14:50:00Z I! Loaded outputs: influxdb (2x)
2025-12-17T14:50:00Z I! Tags enabled: IP=0.0.0.0 environment=VAL host=hostname.example.com machine_type=physical os_type=Win32NT os_version=Microsoft Windows Server 2022 Standard 10.0.20348.0 region=N/A
2025-12-17T14:50:00Z W! Deprecated inputs: 0 and 1 options
2025-12-17T14:50:00Z I! [agent] Config: Interval:10s, Quiet:false, Hostname:"hostname.example.com", Flush Interval:10s
2025-12-17T14:50:00Z W! [agent] The default value of 'skip_processors_after_aggregators' will change to 'true' with Telegraf v1.40.0! If you need the current default behavior, please explicitly set the option to 'false'!
2025-12-17T14:58:21Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Idle Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T14:58:21Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Processor Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T15:04:30Z I! [agent] Hang on, flushing any cached metrics before shutdown
2025-12-17T15:04:30Z I! [agent] Stopping running outputs
2025-12-17T15:04:31Z W! Strict environment variable handling will be the new default starting with v1.38.0! If your configuration works with strict handling or you don't use environment variables it is safe to ignore this warning. Otherwise please explicitly add the --non-strict-env-handling flag!
2025-12-17T15:04:31Z I! Loading config: C:\\Program Files\\InfluxData\\telegraf-1.37.0\\telegraf.conf
2025-12-17T15:04:31Z W! DeprecationWarning: Option "ignore_protocol_stats" of plugin "inputs.net" deprecated since version 1.37.0 and will be removed in 1.45.0: option is ignored
2025-12-17T15:04:31Z I! Starting Telegraf 1.37.0 brought to you by InfluxData the makers of InfluxDB
2025-12-17T15:04:31Z I! Available plugins: 242 inputs, 9 aggregators, 35 processors, 26 parsers, 67 outputs, 7 secret-stores
2025-12-17T15:04:31Z I! Loaded inputs: cpu disk diskio internal mem net netstat procstat system win_perf_counters
2025-12-17T15:04:31Z I! Loaded aggregators:
2025-12-17T15:04:31Z I! Loaded processors:
2025-12-17T15:04:31Z I! Loaded secretstores:
2025-12-17T15:04:31Z I! Loaded outputs: influxdb (2x)
2025-12-17T15:04:31Z I! Tags enabled: IP=0.0.0.0 environment=VAL host=hostname.example.com machine_type=physical os_type=Win32NT os_version=Microsoft Windows Server 2022 Standard 10.0.20348.0 region=N/A
2025-12-17T15:04:31Z W! Deprecated inputs: 0 and 1 options
2025-12-17T15:04:31Z I! [agent] Config: Interval:10s, Quiet:false, Hostname:"hostname.example.com", Flush Interval:10s
2025-12-17T15:04:31Z W! [agent] The default value of 'skip_processors_after_aggregators' will change to 'true' with Telegraf v1.40.0! If you need the current default behavior, please explicitly set the option to 'false'!
2025-12-17T16:43:10Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Idle Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T16:52:10Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Interrupt Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T16:52:10Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Privileged Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T16:52:10Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% User Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T16:52:10Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Processor Time", instance: *, will skip metric: A counter with a negative denominator value was detected.
2025-12-17T16:52:20Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Processor Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T16:59:01Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Idle Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T17:07:40Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Interrupt Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T17:07:40Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Privileged Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T17:07:40Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% User Time", instance: *, will skip metric: A counter with a negative value was detected.
2025-12-17T17:07:40Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Processor Time", instance: *, will skip metric: A counter with a negative denominator value was detected.
2025-12-17T17:07:50Z W! [inputs.win_perf_counters] Error while getting value for counter "\\Processor(*)\\% Processor Time", instance: *, will skip metric: A counter with a negative value was detected.

System info

Telegraf 1.37.0 Windows Server 2022 Standard 21H2 20348.4529 Intel(R) Xeon(R) Silver 4210 CPU @ 2.20GHz 2.19 GHz (2 processors)

Docker

No response

Steps to reproduce

  1. Install Telegraf latest version on a windows system with 20 cores and 40 logical processors
  2. Configure either inputs.cpu or inputs.win_perf_counters plugin to capture cpu percentage usage

Expected behavior

Correct CPU usage values are reported by telegraf

Actual behavior

telegraf reports more than 100% usage and also report negative values

Image

Additional info

I noticed that the issue only happens on a host with more than 20 logical processors , it has 20 cores and 40 logical processors.
I have another machine with 20 cores and 20 logical processors and it doesn't show this behavior.

Activity

  1. added
    bug
    on Dec 17, 2025
  2. self-assigned this
    on Jun 5, 2026
  3. srebhan commented on Jun 8, 2026

    @srebhan
    Member

    @jihed-bengharbia-qiminfo is this behavior reproducible?

    I assume this happens because some cores are at sleep when Telegraf queries the data and/or the Windows performance counters overflow (which would produce a negative value)... To verify this I would need some debug information.
    Are you willing to test a debug-version of Telegraf and send the output?

  4. jihed-bengharbia-qiminfo commented on Jun 17, 2026

    @jihed-bengharbia-qiminfo
    Author

    Hello @srebhan ,
    yes it's reproducible , and yes I can test a debug version of telegraf .

  5. srebhan commented on Jun 22, 2026

    @srebhan
    Member

    @jihed-bengharbia-qiminfo let's first concentrate on the inputs.cpu plugin as the performance counters might have additional issues (such as the overflows you see in the logs)...

    Can you please post your inputs.cpu config that leads to the issues mentioned?!? Furthermore, is it possible for you to log the actual raw metrics on the machine e.g. by adding an output with

    [[outputs.file]]
      namepass = ["cpu"]
      files = ['...\metrics.out']
      data_format = "influx"

    and post the created file here?

    Important

    Replace the files setting above with a path that works for you!

  6. srebhan commented on Jul 7, 2026

    @srebhan
    Member

    @jihed-bengharbia-qiminfo the issue might be caused by in issue in the underlying library (shirou/gopsutil#887). The fixed version of the library is used in Telegraf v1.38.4 and later so can you please repeat your test with a newer version of Telegraf!?

  7. skartikey commented on Jul 7, 2026

    @skartikey
    Contributor

    We dug into this further and there are actually two separate problems mixed together in this issue.

    The first one explains the per-CPU garbage and the "current total CPU time is less than previous total CPU time" errors. Before Telegraf 1.38.4 the underlying library was not processor-group aware on machines like this one (2 sockets, 40 logical processors), so between two gathers the same cpuN label could refer to a different physical core and the deltas went wild. That is the gopsutil bug @srebhan linked above (shirou/gopsutil#887) and it is fixed in Telegraf 1.38.4 and later.

    The second one survives the upgrade: tiny negative values on cpu-total only, in the order of -5e-10. Those come from precision loss inside gopsutil. For cpu-total it converts the Windows counters to float64 too early and then computes kernel - idle, so after a few days of uptime the rounding error is large enough to make the counter look like it went backwards. The per-CPU path subtracts the raw integers first, which is why individual cores are not affected. I filed this upstream with a full analysis and a proposed fix: shirou/gopsutil#2110. Once that lands and Telegraf picks up the new gopsutil release, this part goes away too.

    The win_perf_counters warnings in the log are a separate PDH counter story and are not covered by either fix, so I would keep this issue scoped to inputs.cpu.

  8. srebhan commented on Jul 9, 2026

    @srebhan
    Member

    @jihed-bengharbia-qiminfo please run the debugging binary in PR #19249 with the following config

    [agent]
      logfile = '...\issue-18141.log'
      interval = "10s"
    
    [[inputs.cpu]]
      log_level = "trace"
    
    [[outputs.discard]]

    and provide the resulting log file.

    Important

    Please adapt the logfile setting to a location convenient for you and set the interval to match your usual config!

    You can check if an incident occurred by searching for the following text in the log-file

    [issue18141] Detected invalid field values!
    

    Background: @skartikey and myself checked the plugin code as well as the gopsutil code and (besides of the PR above) cannot see any issue. I also double-checked the (sparse) Windows API documentation and can confirm that processing matches the description. So either there is some reordering of the CPUs (that should not happen according to the Windows documentation) or a misinterpretation of the values returned. Therefore, I added some trace output to provide the raw numbers returned by gopsutil.

  9. skartikey commented on Jul 20, 2026

    @skartikey
    Contributor

    Follow-up on the second problem I described above, the "current total CPU time is less than previous total CPU time" errors on cpu-total.

    The cause was in gopsutil: Times(percpu=false) did the kernel - idle subtraction in floating point, and on a machine with some uptime the rounding error varies between calls, so the values are not monotonic even though the Windows counters are. The fix subtracts the 64-bit tick counts as integers instead. Simulated over 100000 intervals it goes from 27674 phantom decreases to 0.

    Merged upstream as shirou/gopsutil#2111, but not released yet and we are on v4.26.6. I will open the bump here once it lands in a release.

    This does not cover the win_perf_counters negative-counter warnings, which are separate, and the large over-100% readings should already be fixed by the processor-group change in v1.38.4. @jihed-bengharbia-qiminfo, the trace log @srebhan asked for is still worth having to confirm nothing else remains.

  10. srebhan commented on Aug 3, 2026

    @srebhan
    Member

    @jihed-bengharbia-qiminfo please test the binary in PR #19372, available for 72h once CI finished all tests, and let me know if this fixes the issue!

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

Labels

bug

Type

No type

Projects

No projects

    Milestone

    No milestone

    Relationships

    None yet

    Development

    No branches or pull requests

    Issue actions