You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
factory watch observed a runtime failure of the factory itself from local evidence: signal lifecycle, stage triage-ticket, triage_endpoint_unavailable. Filed automatically; no human has looked at it yet.
The factory pass completes without triage_endpoint_unavailable at stage triage-ticket, and factory watch --dry-run no longer reports fingerprint a60ef4d592b6.
Triage: This is a self-referential infrastructure failure: the factory's own triage stage failed with triage_endpoint_unavailable, meaning the endpoint the factory calls to perform triage was not reachable. The evidence only records the symptom (a mechanism_failure exit at stage triage-ticket) and does not identify the root cause. It could be a transient network outage, a missing/invalid credential, a misconfiguration, or an external service being down. Until the root cause is known, it is impossible to tell whether this is a code fix, a config/credential fix, or an environmental condition that will resolve on its own, so the reporter must be asked for the specifics before any action can be taken.
Question: What is the triage endpoint that the factory calls at stage triage-ticket, and why was it unavailable (network outage, missing/invalid credential, misconfiguration, or external service down)? Is this a transient failure that recovers on retry, or a persistent condition?
Activity
mikeroysoft-agent commentedon Oct 17, 2026
Triage: This is a self-referential infrastructure failure: the factory's own triage stage failed with
triage_endpoint_unavailable, meaning the endpoint the factory calls to perform triage was not reachable. The evidence only records the symptom (a mechanism_failure exit at stage triage-ticket) and does not identify the root cause. It could be a transient network outage, a missing/invalid credential, a misconfiguration, or an external service being down. Until the root cause is known, it is impossible to tell whether this is a code fix, a config/credential fix, or an environmental condition that will resolve on its own, so the reporter must be asked for the specifics before any action can be taken.Question: What is the triage endpoint that the factory calls at stage triage-ticket, and why was it unavailable (network outage, missing/invalid credential, misconfiguration, or external service down)? Is this a transient failure that recovers on retry, or a persistent condition?
mikeroySoft commentedon Oct 19, 2026
Duplicate of mikeroySoft/factory#261 / ROCm#262 (host condition; no longer filed since ROCm#281). Stopping watch from filing engine bugs here is tracked in mikeroySoft/factory#311. Engine bugs are tracked in mikeroySoft/factory.