You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
To power a channel-density / electrode-system filter on the Discover page, the D1 catalog needs two new per-dataset fields the website can filter and sort on. Today neither channels nor n_channels appears on any /datasets row (verified across all 646 rows), so the website's "Has 10-20 montage" sidebar control is a dead stub and the plumbed channels range filter has nothing to act on.
Requested fields
n_channels (int) — representative EEG/MEG channel count for the dataset (e.g. modal value across *_channels.tsv, or max). Enables a density filter: low (≤32), standard (33–64), high (65–128), high-density (129+).
electrode_system / montage (string enum) — best-effort classification of the cap/montage, e.g. 10-20, 10-10, 10-05, biosemi, egi-geodesic, other. Derivable from:
CapManufacturer / CapManufacturersModelName in *_eeg.json when present.
Why this matters to users
Researchers care more about "is this high-density?" than "is it exactly 10-20." A density dropdown plus a system dropdown (geodesic/BioSemi/10-xx) lets people find caps comparable to their own. The website filter UI is being built now in a disabled/guarded state and will light up automatically once these fields land.
Website side
FilterState already carries a channels: {min,max} range (URL params c_min/c_max); only the UI + data are missing.
Discover already pages the full filtered set client-side for range filters (see website listAllDatasets), so no count/pagination work is needed once the field exists.
Classifier (channel-montage.ts, MNE-grounded label sets) computes both columns during enrichment and via the admin sweep; the BioSemi false-positive found in the dry-run was fixed (require bank-label majority).
The website channel-density + electrode-system filter consumes these columns.
The residual unpopulated rows (iEEG predicate over-match, orphaned nm0002xx repo pointers, annexed/sparse channels.tsv) are diagnosed and tracked in #867 — a follow-up, not a blocker for this feature. Closing.
Activity
Merge pull request #863 from nemarOrg/feature/issue-854-epic-channel-…
feat(admin): add ?reset=1 to channel-montage-sweep
neuromechanist commentedon Jun 29, 2026
Delivered + backfilled on prod
The epic is complete and the production backfill has converged (
channel-montage-sweep→remaining: 0):0054(n_channels,electrode_system) +0055(channel_montage_checked_at) live (releases v0.8.71 / v0.8.72).channel-montage.ts, MNE-grounded label sets) computes both columns during enrichment and via the admin sweep; the BioSemi false-positive found in the dry-run was fixed (require bank-label majority).10-10: 252,egi-geodesic: 40,10-20: 31,10-05: 23,biosemi: 11,other: 35.The website channel-density + electrode-system filter consumes these columns.
The residual unpopulated rows (iEEG predicate over-match, orphaned
nm0002xxrepo pointers, annexed/sparsechannels.tsv) are diagnosed and tracked in #867 — a follow-up, not a blocker for this feature. Closing.feat(api): channel/montage columns + projection
feat(enrich): compute channel count + electrode system
feat(admin): channel/montage backfill sweep
fix(enrich): don't classify 10-20 + A2 ref as BioSemi