Description
While testing the Girder Analysis Results section, the Member dropdown, Load Case/Combination dropdown, force radio buttons, and Display Values options were tested.
The controls could be selected, but the expected changes were not reflected in the CAD view, girder highlighting, analysis plots, or displayed values.
Steps to Reproduce
- Open OsdagBridge and complete the required inputs.
- Open Girder Analysis Results.
- Select different girders from the Member dropdown.
- Select different load combinations.
- Select different force radio buttons.
- Select Max, Min, All, and Summary under Display Values.
- Observe the CAD view, plots, and displayed results.
Expected Behavior
Changing a member, load combination, force type, or display-value option should update the corresponding CAD highlighting, analysis plot, or displayed values.
Actual Behavior
The controls respond to selection, but no visible update was observed in the CAD, highlighting, plots, or displayed values.
Affected Tasks
- Task 94 — Member and Load Case Dropdowns
- Task 95 — Force Radio Buttons
- Task 96 — Display Values
Evidence
https://drive.google.com/file/d/13Rl74kX_oS2Uieo0N05CHskWd0nRxYlH/view?usp=drive_link
Description
While testing the Girder Analysis Results section, the Member dropdown, Load Case/Combination dropdown, force radio buttons, and Display Values options were tested.
The controls could be selected, but the expected changes were not reflected in the CAD view, girder highlighting, analysis plots, or displayed values.
Steps to Reproduce
Expected Behavior
Changing a member, load combination, force type, or display-value option should update the corresponding CAD highlighting, analysis plot, or displayed values.
Actual Behavior
The controls respond to selection, but no visible update was observed in the CAD, highlighting, plots, or displayed values.