v2 site view is a wireframe of the approved design, not the design #112

Description

@pseudoseed

Problem. Comparing the shipped /v2/ render against codev/research/v2-mockups/01-site.png side by side, the structure and palette match but almost everything that makes the design readable was dropped. It reads as a wireframe of the mockup.

Spec 83 checked tokens, containment, rust discipline and D8 chrome absence — all of which passed. Nothing checked fidelity against the mockup itself, which is why this got through review.

Missing, all present in the approved design:

Approved (01-site.png) Shipped
Header: Porch mark, SITE REGISTER · 2 MACHINES · 5 WORKSPACES · 11 BUILDERS, FIND NODE ⌘K, ADD MACHINE, gate badge localhost THIS MACHINE and nothing else
tower-01 MAC STUDIO · FOREMAN'S RIG + ONLINE · 41% LOAD no machine metadata at all
WORKSPACE / CHECKOUT with icon bare CODEV-1455
architect/checkout-v3 with icon and status dot bare main
builder/pay-2201 bare spir-83
Sparkline as visible bars of varying height a row of dots, effectively invisible
Offline machine shows RECONNECT TO RESUME in its empty lot nothing
Plots sized to content, ~3 across, compact stretched to the tallest in the row (#111)

The naming convention is the biggest single loss. workspace/, architect/ and builder/ prefixes are how the design tells four node kinds apart at a glance. Without them every row is an undifferentiated string, and the hierarchy has to be inferred from indentation alone — which is the outline FR-1 explicitly rejects.

Sparklines. .spark i bars render at the trace value, so an all-zero trace is zero-height and reads as dots. The mockup's idle builders show a visible flat baseline (....... at a consistent low height) rather than nothing. An idle builder should look idle, not look broken.

Not in scope, correctly omitted: gate queue rail, live panes, find-node, add-machine. Those are later units per D8 and are absent rather than stubbed, which was the right call.

Scope of a fix. Restore the label prefixes and icons, the header bar with its counts, machine metadata where the wire carries it (and omit what it does not — do not invent 41% LOAD), a visible idle baseline for sparklines, and the offline-lot placeholder. Fix #111 in the same pass since it is one line and compounds all of this.

Testing. A fidelity check the current suite has no equivalent of: render a fixture matching the mockup's data and assert the label prefixes, header counts and sparkline baseline are present. Component tests that assert only "the name renders" cannot catch a missing prefix.

Found by the architect comparing renders after merge. Spec 83's review verified tokens and structure and never compared against the mockup — that gap is the reason this shipped.

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    area/dashboardTower web dashboardfork-onlyDeliberately not upstreamed to cluesmith/codev

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions